Optimal Linear Control Applied to a pH and Volume Control Process: An Economic Feasibility Assessment
DOI:
https://doi.org/10.61467/2007.1558.2027.v18i1.1485Keywords:
Modelo lineal, control por realimentación de estados, control de pH, linear model, state-feedback control, pH controlAbstract
This work presents a linear control strategy applied to an agitated tank reactor for pH and volume regulation, based on the linearization of a mathematical model in which both concentration and volume are considered time-varying variables. The linearization is performed around an operating point in order to compute the gains of an LQR controller. Different penalty matrices Q and R are evaluated to obtain different closed-loop plant performances. The pH setpoints were selected according to the Mexican Official Standard NOM-002-SEMARNAT-1996. The simulation results provide evidence of the feasibility of the proposed approach.
Spanish-language metadata / Metadatos en español
Título en español:
Control lineal óptimo aplicado a un proceso de control de pH y volumen: evaluación de viabilidad económica
Resumen:
Este trabajo presenta una estrategia de control lineal aplicada a un reactor de tanque agitado para la regulación del pH y el volumen, basada en la linealización de un modelo matemático en el que tanto la concentración como el volumen se consideran variables dependientes del tiempo. La linealización se realiza en torno a un punto de operación con el fin de calcular las ganancias de un controlador LQR. Se evalúan diferentes matrices de penalización Q y R para obtener distintos desempeños de la planta en lazo cerrado. Los valores de referencia de pH se seleccionaron de acuerdo con la Norma Oficial Mexicana NOM-002-SEMARNAT-1996. Los resultados de simulación proporcionan evidencia de la viabilidad del enfoque propuesto.
Palabras Claves:
Modelo lineal, control por realimentación de estados, control de pH, control de volumen, LQR, viabilidad económica.
Smart citations:
SciteAI.
Dimensions.
Open Alex.
References
Ali, E. (2001). pH control using PI control algorithms with automatic tuning method. Chemical Engineering Research and Design, 79(5), 611–620. https://doi.org/10.1205/02638760152424398
Ashoori, A., Moshiri, B., Khaki-Sedigh, A., & Bakhtiari, M. R. (2009). Optimal control of a nonlinear fed-batch fermentation process using model predictive approach. Journal of Process Control, 19(7), 1162–1173. https://doi.org/10.1016/j.jprocont.2009.03.006
Cuellar Hernández, M. de L., Morales Ramírez, D., & Alvarado Lagunas, E. (2023). Impacto de la responsabilidad social empresarial en el desempeño financiero: Evidencia de México. Análisis Económico, 38(99), 101–117. https://doi.org/10.24275/uam/azc/dcsh/ae/2023v38n99/Cuellar
Hermansson, A. W., & Syafiie, S. (2015). Model predictive control of pH neutralization processes: A review. Control Engineering Practice, 45, 98–109. https://doi.org/10.1016/j.conengprac.2015.09.005
Kalman, R. E. (1960). Contributions to the theory of optimal control. Boletín de la Sociedad Matemática Mexicana, 5, 102–119
Kim, J. W., Park, B. J., Oh, T. H., & Lee, J. M. (2021). Model-based reinforcement learning and predictive control for two-stage optimal control of fed-batch bioreactor. Computers & Chemical Engineering, 154, 107465. https://doi.org/10.1016/j.compchemeng.2021.107465
Lee, J. H., Lee, I. Y., Kim, M. K., & Park, Y. H. (1999). Optimal pH control of batch processes for production of curdlan by Agrobacterium species. Journal of Industrial Microbiology and Biotechnology, 23(2), 143–148. https://doi.org/10.1038/sj.jim.2900714
Loh, A.-P., De, D. S., & Krishnaswamy, P. R. (2001). pH and level controller for a pH neutralization process. Industrial & Engineering Chemistry Research, 40(16), 3579–3584. https://doi.org/10.1021/ie000193z
Luyben, W. L. (1989). Process modeling, simulation, and control for chemical engineers (2nd ed.). McGraw-Hill.
Rakshit, S. K., & Sahai, V. (1991). Optimal control strategy for the enhanced production of cellulase enzyme using the new mutant Trichoderma reesei E-12. Bioprocess Engineering, 6, 101–107. https://doi.org/10.1007/BF00369062
Secretaría de Medio Ambiente y Recursos Naturales. (2022, 11 de marzo). Norma Oficial Mexicana NOM-001-SEMARNAT-2021, que establece los límites permisibles de contaminantes en las descargas de aguas residuales en cuerpos receptores propiedad de la nación. Diario Oficial de la Federación. Documento oficial en el Diario Oficial de la Federación
Secretaría de Medio Ambiente, Recursos Naturales y Pesca. (1998, 3 de junio). Norma Oficial Mexicana NOM-002-ECOL-1996, que establece los límites máximos permisibles de contaminantes en las descargas de aguas residuales a los sistemas de alcantarillado urbano o municipal. Diario Oficial de la Federación. https://www.profepa.gob.mx/innovaportal/file/3295/1/nom-002-semarnat-1996.pdf?utm_source=chatgpt.com
Wu, Q., & Cui, Z. (2010). Nonlinear compensator based PI controller for pH neutralization reaction process. In 2010 2nd International Conference on Industrial and Information Systems (Vol. 2, pp. 71–74). IEEE. https://doi.org/10.1109/INDUSIS.2010.5565677
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 International Journal of Combinatorial Optimization Problems and Informatics

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.